Maximum number of verification intervals: nLC = 3000
Combined error: 0,02% of Full Scale Output (F.S.)
Full Scale Output: 2mV/V +/- 0,1%
Temperature effect on zero: 0,0013% /°C
Temperature effect on full scale output: 0,0014% /°C
Compensated Temperature Range: –10°C/+40°C
Operating Temperature Range: -20°C/+60°C
Creep error after 4 hours: 0,03% F.S.
Maximum tolerated excitation voltage: 10 VDC
Input Resistance: 1100 Ohm
Output Resistance: 1000 Ohm
Zero balance: +/-1% F.S.
Insulation Resistance: >5000 MOhm
Safe Overload: 150% F.S.
Ultimate Overload: 300% F.S.
4-wire shielded cable, 5m long, 5mm diameter
ATEX VERSION
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.